EDI Detectors

Inductive Loop Detectors
EDI manufacturers the highest quality loop detectors for the gate and door industry.

LMA-1250 Specifications

DEFLECTOMETER™:
The front panel 7-segment LED DEFLECTOMETER™ provides visual feedback and assistance for setting the correct sensitivity, reading the frequency of the loop, reporting Loop Faults, and indicating Delay & Extension Timing functions.

Sensitivity Meter:
With a typical size vehicle over the roadway loop, the DEFLECTOMETER™functions as a Sensitivity Meter. The optimum sensitivity setting should provide a reading of “5”. You can adjust the DEFLECTOMETER™reading by using the front panel UP or DOWN sensitivity buttons. Automatic quantitative feedback of the loop system operation ensures that the detector is set to the most optimum sensitivity level to detect all vehicles, including motorcycles and high-bed vehicles.

Frequency Meter:
Following power-up or reset, the DEFLECTOMETER™ will indicate a 2 or 3 digit number (quickly flashes) that indicates the loop frequency of the loop & loop network. Keeping your loops separated by at least 5 KHz avoids crosstalk problems and future service calls.

Ten (10) Levels of Sensitivity:
10 levels of sensitivity (0 to 9) can be easily set using the UP or DOWN push buttons.

Two Models Cover ALL Voltages:

LMA-1250-LV operates on 12VDC, 24VDC, and 24VAC LMA-1250-HV operates on 120VAC and 240VAC

Advanced Loop Diagnostics:
The Loop Fault Monitor continually checks the integrity of the loops and will report and store three types of loop faults; Open Loops, Shorted Loops, and 25% sudden changes in inductance.

Loop Fault Memory:
The Loop Fault Memory uses internal Non-Volatile memory to store and display the current and previous loop faults utilizing the front panel “Loop Fault” LED and DEFLECTOMETER™. A power loss or reset will not delete this memory. A must for troubleshooting!

Call Output Memory:
The detector will not drop a Call state if power is lost for a minimum of 4 seconds or less.

Delay & Extension Timing:
A 2-second Call “Delay” time and 2, 5, or 10-second Call “Extension” time can be provided.

EDI Detectors

DEFLECTOMETER™ Technology

EDI's LMA Detector Series

View Spec Sheets for:

LMA-1150
LMA-1250
LMA-1250LP
LMA-1400
LMA-1800
LMA-1800LP

For more information contact EDI:

Eberle Design Inc.

3819 East La Salle Street
Phoenix, AZ 85040

Telephone: (480) 968-6407
Fax: (602) 437-1996
Website: http://www.editraffic.com/
E-mail: info@editraffic.com